Wednesday, August 12, 2009

FREE Chemical Engineering Digital Issue for Aug 2009

Display problem ? Click HERE




FREE Chemical Engineering Digital Issue for August 2009 has been released !

Chemical Engineering has just released FREE August 2009 issue. If you are subscriber of
Chemical Engineering, you should have received similar notification.


***********************

Interesting articles for this month :

FAYF - Adsorption
This one-page guide explains various adsorbent properties and provides the corresponding
equations

Viscosity: The Basics
An important concept, sometimes forgotten, is that viscosity is not a single-point measurement.
Basic concepts and terminology are reviewed and techniques for quantifying viscosity are addressed

REACH: Looking Beyond Pre-registration
The next steps to ensuring compliance are significantly more complex

Keeping Cooling Water Clean
Proper monitoring and control of water chemistry is essential

Today’s SIS: Integrated Yet Independent
Bringing process control and instrumented safety systems together while still keeping them separate provides benefits beyond risk reduction

Monitoring Air Emissions
New requirements are spurring strong demand in air pollution monitoring

***********************

TIPS
If you are subscriber, you may access previous digital releases. Learn more in "How to Access Previous Chemical Engineering Digital Issue".

If you yet to be subscriber of Chemical Engineering, requested your FREE subscription via this link (click HERE). Prior to fill-up the form, read "Tips on Succession in FREE Subscription".

Related Post

Sunday, August 9, 2009

Relate Heat Radiation Level and Temperature

Display problem ? Click HERE

Recommended :
-
Subscribe FREE - Chemical Engineering
- Tips on Succession in FREE Subscription

Earlier post "Heat Radiation For Pain & Blistering Threshold" and "Personnel Exposure Time For Heat Radiation" have discussed the heat radiation level lead to plant personnel pain and blistering threshold within an exposure time. Heat radiation design criteria for personnel exposure has been proposed for continuous and emergency exposure. Flare radiation run using software i.e. FLARESIM or calculation using Brzustowski and Sommer method, heat radiation level will be estimated and presented. For equipment, instrument, piping, painting, steel structure, etc expose to flare radiation will experienced increase temperature.

How shall a heat radiation level relates to temperature ?

Heat level (Et) at recepting location can be related to the sum of radiation heat (Er) plus convection heat (Ec).

Et = Er + Ec

For unit area (m2),

qt = qr + qc

where
qt = total heat flux at receptor (kW/m2)
qr = radiation heat flux at receptor (kW/m2)
qc = convection heat flux at receptor (kW/m2)

Radiation heat flux,
qr = sigma x (T4 - Ta4)

Convection heat flux
qc = (h / e) x (T - Ta)

where
sigma = stefan-Boltzman constant = 5.67 e -11 (kW/m2K)
h = convective heat transfer co-efficient = 0.007 (kW/m2K) at zero wind speed
e = Emissivity (0.8-0.9 for copper or rusted CS pipe, 0.1-0.2 for polished SS pipe)
T = Surface temperature (K)
Ta = Ambient temperature (K)

Therefore
qt = sigma x (T4 - Ta4) + (h / e) x (T - Ta)

If a heat radiation level is known at particular location, the corresponding temperature may be estimated using above equation.

Related Topic

Monday, August 3, 2009

Personnel Exposure Time For Heat Radiation

Display problem ? Click HERE

Recommended :
Subscribe FREE - Chemical Processing

Earlier post "Heat Radiation For Pain & Blistering Threshold" has briefing discussed about the exposure time for heat radiation level which lead pain and blister threshold. Equations have been proposed in order to link between exposure time for dedicated heat radiation. Example, with heat radiation of 6.3 kW/m2 (2 000 Btu/h·ft2), the pain threshold is reached in 8 s and blistering occurs in 20 s.

Maximum allowable personnel exposure time to particular heat radiation level proposed in API RP 521 (previous revision - 1997) and API Std 521 (latest revision - May 2008) are marginally different. Detail list out as follow

Heat
Radiation
(kw/m2)
API Rp 521
(March 1997)
API Std 521
(May 2008)
9.45
Exposure must be limited to a few (approx. six) seconds, sufficient for escape only. May consider tower or structure provide some degree of shielding.
Required urgent emergency action. Radiation shielding and/or special protective apparel (e.g. a fire approach suit) required
6.31Emergency actions lasting up to 1 minutes without shielding but with appropriate clothing.
Emergency actions lasting up to 30s without shielding but with appropriate clothing.
4.73
Emergency actions lasting up to several minutes without shielding but with appropriate clothing.Emergency actions lasting 2 min to 3 min without shielding but with appropriate clothing.
1.58personnel with appropriate clothing can be continuously exposedpersonnel with appropriate clothing can be continuously exposed

Above listing shows that latest API Std 521 has more stringent requirement compare to previous revision (1997), specifically for 6.31 and 4.73 kW/m2. The maximum allowable exposure time limit have been reduced. Continuous exposure limit remain unchanged.

Emergency Exposure
Maximum allowable exposure heat radiation of 6.31 and 4.73 kW/m2 (during emergency scenario) have been used as criteria in determining sterile area, an area around flare stack which no personnel shall be around without any personnel protective apparel. For conservative design and/or expect potential increase in flaring rate in future, a limit of 4.73 kW/m2 may be used. For common design, heat radiation limit of 6.31 kW/m2 is widely used. In general, maximum allowable heat radiation of 9.46 kW/m2 will be limited at the flare stack base where personnel may access to sterile area with proper personnel protective apparel.

Continuous Exposure
For continuous exposure, operator is assumed wearing appropriate clothing in a plant. Heat radiation at any location shall be limited to 1.58 kW/m2.

Related Topic

Sunday, July 26, 2009

Heat Radiation For Pain & Blistering Threshold

Display problem ? Click HERE

Recommended :Flare is commonly installed in oil and gas process plant to burn hydrocarbon and/or toxic gas to avoid formation of combustible mixture, to minimize green house effect (GHE), to minimize health hazards to personnel on site, etc. Flaring hydrocarbon gas may generate carbon dioxide & water for complete combustion and soot (contribute to smokeless level) & unburnt components (contributes to toxic environment) for incomplete combustion. Besides, heat and noise are generated and radiated and transmitted around the flare tip.

Heat radiated from flare may transmitted in sphere form around the flare tip. Along the transmission, the energy is distributed in sphere form and this lead to reduction in heat radiation level (heat flux, kW/m2). Personnel or equipment along the transmission path will expose to this heat radiation. Personnel or equipment closer to flare tip will experience higher heat radiation level.

With studies conducted by Stoll and Greene (1958), following graph relate heat radiation versus time for Pain threshold and Blister threshold. With heat radiation of 6.3 kW/m2 (2 000 Btu/h·ft2), the pain threshold is reached in 8 s and blistering occurs in 20 s.



The following equation derived from above graph and can be used to relates heat radiation with time for pain and blister thresholds.

Pain threshold :
q = 25.544 x t -0.6742

Blister threshold :
q = 75.691 x t -0.8399

where :
q = heat radiation (kW/m2)
t = time (seconds)


Ref :
(i) A. M. STOLL and L. C. GREEN, The Production of Burns by Thermal Radiation of Medium Intensity, Paper Number 58-A-219, American Society of Mechanical Engineers, New York, 1958

Related Topic

Saturday, July 25, 2009

Pneumatic Test Failure in Mississippi Pipeline Project

Display problem ? Click HERE

Recommended :
Subscribe FREE - Chemical Processing

An explosion caused by pneumatic test failure has occurred in Shanghai LNG Terminal on Feb 06 2009. This accident has resulted one worker killed and fifteen others injured.

Again it was heard that another pneumatic test failure has occurred in Mississippi in July 2009 and lead to at least one fatality and three others injured during a pneumatic test failure. The following photos show how severe is the destruction of pneumatic test failure.



Overall scene


Air-lifted pipeline


Twisted metal pipe

For those who intended to conduct pneumatic test, really have to ensure that proper procedure is followed. Ensure personnel who are not directly involved in the testing process are removed from the area and not allowed in the area for any reason. If you not involved directly in pneumatic test, please be alert and move away from the testing location.

Following are collection of article that helps you to educate yourself or your operators related to Pneumatic test :

Pneumatic Test During Pre-commissioning
This article has brief introduction about pneumatic test related procedure, safety concern, test pressure level, etc

Pneumatic Test Accident in Singapore
On May 22, 2002, a fatal accident occurred in Singapore involving the failure of a refrigerant receiver during a pneumatic test. In light of this incident, it is appropriate to again remind our readers of the hazards involved in pneumatic tests and to review the precautions that must be taken in conducting such tests.

Hazards of Trapped Pressure and Vacuum
A leak test on a heat exchanger was being conducted using low pressure gas when the tube bundle was ejected with great force striking two employees. One of them died on massive internal injuries...

Pipeline fails under air pressure test - Kills worker
Two workers had completed laying a 30 metre length of 300 mm diameter PVC pipe, in order to connect it to an existing steel pipe, along a suburban roadside. The pipe was then to be pneumatically tested up to a pressure of 690 kPa (100 psi)...

Pneumatic Test Operation Maintenance

This tank is intended for use vented to atmosphere. For outdoor applications, install a weatherproof vent hood or cap on the vent riser pipe and on the interstitial space vent of double wall tanks.

Pneumatic Test - Incident in Brazil
Incident happened in a non-ExxonMobil facility in Brazil during a pneumatic test of the tank associated piping. A blind was NOT installed to isolate the ...
Pdf

Pneumatic Test - IncidentASTM A1047 / A1047M - 05
ASTM A1047 / A1047M - 05 Standard Test Method for Pneumatic Leak Testing of Tubing

Read others incident...Click HERE

Related Post

Sunday, July 19, 2009

FREE Chemical Engineering Digital Issue for July 2009

Display problem ? Click HERE




FREE Chemical Engineering Digital Issue for July 2009 has been released !

Chemical Engineering has just released FREE July 2009 issue. If you are subscriber of Chemical Engineering, you should have received similar notification.

***********************

Interesting articles for this month :

FAYF - Flowmeter Selection
This one-page guide details important facts for selecting a flowmeter

Revamps - Strategies for A Smooth Turnaround
Tie-in opportunities are few and far between. These rules of thumb will help make sure everything and everyone line up in time
Removal of Fouling Deposits on Heat Transfer Surfaces in Coal-Fired Process Heaters and Boilers
When conventional soot blowers are inadequate, an automated shot-blasting system offers a powerful solution
* If you encounter problem in reading this article, you may check this article via this link (for FREE subscriber only).

Disperse Difficult Solids
Recent advances in mixing technology offer increased efficiency in dispersing powdered additives into liquids for both low- and high-viscosity applications

***********************

TIPS
If you are subscriber, you may access previous digital releases. Learn more in "How to Access Previous Chemical Engineering Digital Issue".

If you yet to be subscriber of Chemical Engineering, requested your FREE subscription via this link (click HERE). Prior to fill-up the form, read "Tips on Succession in FREE Subscription".

Related Post

Saturday, July 18, 2009

Energy Input or E-method In Assessing AIV

Display problem ? Click HERE

Recommended :
- Tips on Succession in FREE Subscription
- Subscribes to FREE Hydrocarbon Processing

High frequency acoustic Excitation downstream of pressure reducing device and potential of downstream piping failure on Acoustic Induced Vibration (AIV) has raised concern in many process plant

Earlier post "Extra Attention to Common Point and Similarity on AIV Failure" has discussed the common points and similarity of AIV such as typical failure location, system experienced failure in the past, failure time & period and Mach no. An engineer assessing AIV shall pay extra attention in these factors.

There are several methods have been discussed earlier in assessing AIV problem. There are "D-method" and "D/t-method". These two methods are widely used by many engineering contractor and consultants in many previous projects. There is another method, the Energy Input method or "E-method" which has been introduced in mid 1990.

Energy Input or E-method In Assessing AIV
The "E-method" is focus on the acoustic energy transmitted along the pipe, downstream of pressure reducing devices. The acoustic energy can be measured by Ma2.dP where Ma2 is the Mach number at downstream pipe and dP is the pressure drop across pressure reducing devices. The higher the acoustic energy or Ma2.dP, higher the risk for AIV failure.

Similar to the other two methods, based on data available in Carucci & Mueller (1982) studies, "No failure" and "Failure" points have been plotted in following chart with Ma2.dP versus Pipe Diameter / Wall thickness (D/t).




Note :
1) A "failure" point (54.8, 0.35) is below curve. It is failed on bad welding. No further failure after good welding.


2) Red point are "failure" point and Blue point are "No failure" point

From above chart a clear distinctive limit line can be established. This line may be used to assess potential failure of piping downstream of pressure reducing device. Any point above the line potentially fail on AIV, piping treatment or redesign required to minimise the risk of AIV failure.

*As limit line is straight or following any pattern, a representative equation is yet to be developed.

Related Topic