Tuesday, May 26, 2009

Quick Estimation of Noise Level Across Pressure Reducing Device

Display problem ? Click HERE

Recommended :
- Tips on Succession in FREE Subscription
- Subscribes to FREE Hydrocarbon Processing

Pressure reducing device such as control valve, pressure relief valve, restriction orifice, etc, there will be pressure drop and mass passing through these device, internal acoustic energy is generated and transmitted to downstream piping and potentially lead to severe piping excitation, vibration and stresses on downstream piping and potentially lead to fatigue failure. Internal acoustic energy transmitted along the pipe may also transmitted to through the pipe and emitted as Noise.

One of the common safety requirement is limit the noise level to 85 dBA (Noise level with A-weighted) in continuous exposure and 115 dBA during intermittent exposure. In earlier conceptual or Front End Engineering Design (FEED) stage, the noise level across pressure reducing device may be estimated to determine overall noise control philosophy. The following will present a simple method to estimate noise level generated at 1 meter from a pressure reducing device.

Noise Level Estimation
Noise level at 1 meter from a pressure reducing device can be estimated from Sound Power Level (PWL) as discussed in "Sound Power Level (PWL) Prediction from AIV Aspect". The Sound Power Level will be transmitted across the pipe wall and emitted to atmosphere. There will be noise correction when Sound power is transmitted across pipe wall (metal). The noise correction is subject to wall thickness. Thicker wall will result higher noise correction. Following are typical noise correction for pipe size and wall thickness.

Noise Correction
Nominal Dia.
(Inch)
Wall thickness
(mm)
Noise Correction
(dB)
25
3.38
54
50
3.91
50
100
6.02
50
150
7.12
49
200
8.18
48
250
9.3
47
300
9.53
47
350
9.53
46
450
9.53
46
600
9.53
45
750
9.53
43
900
9.53
43
1050
9.53
42

Noise level at 1 meter from a pressure reducing device,

L1m = PWL - LA

where
PWL = Sound Power Level (from Sound Power Level (PWL) Prediction)
LA = Noise correction from above table

Example
A pressure control valve (PV) passing 100,000 kg/h of gas with molecular weight (MW) of 22. The inlet condition is 87 barg and 50 degC and downstream pressure is about 7 barg. The pipe diameter is 18 inch with wall thickness of 9.53mm, estimate noise level at 1 m from PV.

PWL = 10 x Log [((87-7) / (87+1.01325))^3.6
x (100,000 / 3600)^2
x ((50+273.15)/22)^1.2]
+ 126.1

PWL = 167.5 dB

Noise level at 1m,
L1m = PWL - LA
L1m = 167.5 - 46
L1m = 121.5 dBA

As the noise level at 1m (normal trim) is 121.5 dBA, this is far too big from normal requirement. A low noise trim control valve may be considered and/or acoustic insulation to be provided.